Upgrade Procedure
A screen similar to the following appears:
>>> show config
DEVNBR DEVNAM INFO
--------------------------------------
1 NVR OK
3DZOK
4 CACHE OK
5 MEM OK
16MB = SY=8MB, S0/1=8MB, S2/3=0MB, S4/5= 0MB
6 FPU OK
7ITOK
8 SYS OK
9NIOK
10 SCSI OK
3-RZ24 6-INITR
This information shows an RZ24 drive set to SCSI ID 3.
Write down your system drives and SCSI ID settings here. You
will need them for future use.
Step 2: Shut
Down System
Turn off the system unit by pressing O on the On/Off switch on
the back of the system unit.
Disconnect the power cord from the wall outlet and then from
the system unit.
Caution: After you turn off the system, wait 15 seconds before
unplugging the power cord.
Step 3:
Disconnect
Cables
Disconnect all the cables from the back of the system unit.
7–2 Upgrading a MicroVAX 3100 Model 30