4.6 Installing the outside sensor
4.6.1. Choice of the location
It is important to select a place that allows the sensor to measure the
outside conditions correctly and effectively.
Advised positions:
4 on one face of the area to be heated, on the north if possible
4 half way up the wall in the room to be heated
4 under the influence of meteorological variations
4 protected from direct sunlight
4 easy to access
A
Recommended position
B
Possible position
H
Inhabited height controlled by the sensor
Z
Inhabited area controlled by the sensor
Positions to be avoided:
4 masked by a building element (balcony, roof, etc.)
4 close to a disruptive heat source (sun, chimney, ventilation grid,
etc.)
4.6.2. Connecting the outside sensor
Mount the sensor using the screws and dowels provided.
8800N001-C
8800N002-C
4. Installation
AWHP MIT-IN iSystem
29
24/09/2012 - 300027606-001-01