Loading...
External set points (option G3)
The set point inputs are passive, in other words, an external power source is needed. This can be an active
output, for example from a PLC, or a potentiometer can be used.
0 to 10 V DC input using potentiometer
M
u
l
t
i
-
l
i
n
e
2
4
0
o
r
4
2
4
1
(
C
o
m
m
o
n
)
1
0
V
D
C
0
V
D
C
Ø
Ø
2
0
0
0
O
h
m
¼
W
p
o
t
e
n
t
i
o
m
e
t
e
r
+/-10 V DC input using potentiometer
M
u
l
t
i
-
l
i
n
e
2
4
0
o
r
4
2
4
1
(
C
o
m
m
o
n
)
1
0
V
D
C
-
1
0
V
D
C
Ø
Ø
2
0
0
0
O
h
m
¼
W
p
o
t
e
n
t
i
o
m
e
t
e
r
0
V
D
C
Ø
5.2.4 Multi-inputs
The multi-inputs are placed in slot #7, the terminal numbers for the individual multi-inputs can be seen in the
"Input/output list".
0(4) to 20 mA
Active transducer
0
V
D
C
M
u
l
t
i
-
l
i
n
e
2
M
u
l
t
i
-
i
n
p
u
t
+
1
2
/
2
4
V
D
C
+
-
4
-
2
0
m
A
t
r
a
n
s
d
u
c
e
r
M
e
a
s
u
r
e
m
e
n
t
A
B
C
I
n
-
O
u
t
+
O
u
t
AGC-3 installation instructions 4189340728
UK
Wirings
DEIF A/S
Page 50 of 65
49
51
Table of Contents
Main Page
Default Chapter
2
Table of Contents
2
1 General Information
4
Warnings, Legal Information and Safety
4
Warnings and Notes
4
Legal Information and Disclaimer
4
Safety Issues
4
Electrostatic Discharge Awareness
4
AGC-3 Installation Instructions
4
Factory Settings
5
About the Installation Instructions
5
General Purpose
5
Intended Users
5
Contents and Overall Structure
5
2 General Product Information
6
AGC-3 Product Information
6
Introduction
6
Type of Product
6
Options
6
Standard Functions
6
Operation Modes
6
Engine Control
6
Generator Protection (ANSI)
6
Busbar Protection (ANSI)
7
Display
7
M-Logic
7
Standard and Optional Applications
7
Automatic Mains Failure, AMF
8
Island Operation
8
Fixed Power/Base Load
9
Peak Shaving
9
Load Takeover
10
Mains Power Export (Fixed Power to Mains)
10
Multiple Gensets, Load Sharing
11
Multiple Gensets, Power Management
11
3 Mounting
12
AGC-3 Mounting and Dimensions
12
Mounting of the Unit
12
Unit Dimensions
12
Panel Cutout
13
Drilling Template in MM (Inches)
13
Mounting Instructions
14
Tightening Torques
14
4 Hardware
15
Board Slot Positions
15
Unit Top Side Overview
16
Terminal Strip Overviews
17
Input/Output Lists
23
Slot #1, Power Supply PCB
23
Slot #1, Power Supply PCB - AGC Mains Unit
24
Slot #2, Serial Communication (Option H)
25
Slot #2, External I/O Module (Option H8.2)
26
Slot #3, Load Sharing Control (Option G3)
27
Slot #3, 13 Binary Inputs and 4 Relay Outputs (Option M12)
28
Slot #4, Relay Outputs (Option M14.4, Standard)
29
Slot #4, Analogue Outputs for GOV/AVR or Transducer (Option E1)
29
Slot #4, Analogue Outputs for GOV/AVR or Transducer (Option EF2)
29
Slot #4, Combination Outputs for GOV/AVR or Transducer (Option EF4)
30
Slot #4, PWM Output for GOV and Combination Output for AVR (Option EF5)
30
Slot #4, PWM Output for GOV and Combination Output for AVR (Option EF6)
30
Slot #4, Analogue Outputs for GOV/AVR or Transducer (Option E2)
31
Slot #5, AC Measuring
31
AGC-3 Installation Instructions
31
Slot #5, AC Measuring - AGC Mains Unit
32
Slot #5, AC Measuring - AGC BTB Unit
33
Slot #6, 7 Digital Inputs (Option M13.6)
33
Slot #6, 4 Relay Outputs (Option M14.6)
34
Slot #6, 4 Analogue Inputs (Option M15.6)
34
Slot #6, Analogue Outputs for GOV/AVR or Transducer (Option F1)
34
Slot #7, Engine Interface Card (Standard)
35
Slot #7, Engine Interface Card (Standard) AGC Mains/Btb
36
Slot #8, Engine Interface Communication (Option H5)
37
Slot #8, Cummins Engine Interface Communication (Option H6)
37
Slot #8, 7 Digital Inputs (Option M13.8)
37
Slot #8, 4 Relay Outputs (Option M14.8)
38
Slot #8, External I/O Module (Option H8.8)
38
5 Wirings
39
AC Connections
39
Neutral Line (N)
39
Current Transformer Grounding
39
Fuses
39
Breaker Wiring
39
3-Phase
40
Single Phase
41
2-Phase L1L2
42
2-Phase L1L3 (Split Phase)
43
Island Mode and Power Management (Option G4/G5/G8)
44
Power Management (Option G5), AGC Mains
45
Power Management (Option G5), Dual Mains - AGC Mains
46
Power Management (Option G5), AGC BTB
47
DC Connections
48
Load Sharing Lines (Option G3)
48
Digital Inputs
48
Analogue Inputs
49
Multi-Inputs
50
Digital Inputs
51
Pt100/Pt1000
51
Rmi
51
To 40 V DC
52
RPM Input
52
Stop Coil
53
Transistor Outputs (Open Collector Outputs)
54
Communication
55
CAN Bus (Option G4/G5/G8)
55
Modbus (Option H2)
56
Profibus DP (Option H3)
58
CAN Bus Engine Communication (Option H5)
58
Cummins GCS (Option H6)
59
CAN Bus Engine Communication (Option H7)
60
External I/O Module (Option H8)
61
Display Cable (Option J)
61
6 Technical Information 6.1 Technical Information, AGC-3
62
Technical Specifications
62
Other manuals for Deif AGC-3
General Guidelines For Commissioning
25 pages
Related product manuals
Deif AGC-4
26 pages
Deif AGC 150
38 pages
Deif AGC 200
24 pages
Deif AGC 100
152 pages
Deif AGC-4 Mk II
50 pages
Deif AGC 200 Series
25 pages
Deif ASC Series
26 pages
Deif GC-1F
11 pages
Deif PPM-3
25 pages
Deif SGC 120
76 pages
Deif CGC 400
14 pages
Deif PPU 300
130 pages