34
Cod.: 240.010.0042
DLS / DLS-C Series
The DLS system can be connected to the distribution network only in the countries which is certied for.
The DLS system can be used only respecting all the technical characteristics.
Improper or Unauthorized Use:
Although carefully constructed, all electrical appliances can catch re.
The DLS system is intended for indoors installation.
Optimal operation of the DLS system is ensured at a maximum ambient temperature of 40°C (104°F).
The DLS system must be transported and stored in indoor location with temperature range of -30°C to
+70°C (-22°F and 158°F).
The DLS system must be used in locations with no acids, gases or other corrosive substances.
The DLS system must be used and stored in locations with relative humidity ranging from 5% to 95% wi-
thout condensation.
The DLS system must be transported in locations with relative humidity ranging from 5% to 95%.
The DLS system must be used and stored in locations with atmospheric pressure ranging from 86kPa to
106kPa.
The DLS system must be transported in locations with atmospheric pressure ranging from 70kPa to 106kPa.
The DLS system must be used at a maximum altitude above sea level of 3000m (9750 feet). For altitudes
above 2000m, due to the rarefaction of the air, specic conditions may occur which must be considered
when choosing the place of installation. All installations at altitudes above 2000m must be assessed case
by case considering the following critical issues:
• less efcient cooling;
• decrease in the dielectric strength of the air and, in the presence of high voltages, the creation of
electric arcs;
• presence of cosmic radiation that can affect the correct functioning of the electronic components.