6 Move the cables out of the way to access the cooling fan cable connector on the system board.
Steps
1 Holding the blue touch point, place the cooling fan into the cooling fan cage.
2 Route the cooling fan cable and connect it to the connector on the system board.
Figure 27. Installing cooling fan
Next steps
1 Install the internal riser.
2 Connect the power cable.
3 Ensure all the cables are routed correctly.
4 Install the air shroud.
5 Follow the procedure listed in After working inside your system.
Related links
Installing the internal PERC riser
Installing the air shroud
Intrusion switch
The Chassis Intrusion Switch is activated when the cover of your system is removed while your system is on. The system event logs [SEL]
records the number of times the cover is removed when the system is turned on.