EasyManua.ls Logo

Dell EMC PowerEdge R7525 - Removing the Drive Backplane

Dell EMC PowerEdge R7525
209 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Figure 49. 16 x 2.5-inch drive backplane
1. DST_SB1 (backplane to front PERC) 2. DST_PWR_1 (backplane power and signal cable to system
board)
3. BP_PWR_CTRL (front PERC power and control signal) 4. BP_DST_SA1 (backplane to front PERC)
Figure 50. 24 x 2.5-inch drive backplane
1.
DST_PB6 (PCIe/NVMe connector) 2. DST_PA6 (PCIe/NVMe connector)
3. DST_PB5 (PCIe/NVMe connector) 4. DST_PWR_1 (backplane power and signal cable to system
board)
5. DST_PA5 (PCIe/NVMe connector) 6. DST_PB4 (PCIe/NVMe connector)
7. DST_PA4 (PCIe/NVMe connector) 8. DST_PB3 (PCIe/NVMe connector)
9. DST_PA3 (PCIe/NVMe connector) 10. DST_PB2 (PCIe/NVMe connector)
11. DST_PWR_2 (backplane power and signal cable to system
board)
12. DST_PA2 (PCIe/NVMe connector)
13. DST_PB1 (PCIe/NVMe connector) 14. DST_PA1 (PCIe/NVMe connector)
Removing the drive backplane
Prerequisites
CAUTION:
To prevent damage to the drives and backplane, remove the drives from the system before removing the
backplane.
CAUTION: Note the number of each drive and temporarily label them before you remove the drive so that you can
reinstall them in the same location.
NOTE: The procedure to remove the backplane is similar for all backplane configurations.
1. Follow the safety guidelines listed in the Safety instructions on page 46.
2. Follow the procedure listed in the Before working inside your system on page 47.
3. Remove the backplane cover.
4. If installed,remove the air shroud.
5. Remove all the drives.
6. Remove the cooling fan cage assembly.
7. Disconnect the drive backplane cables from the connector on the system board.
8. Disconnect the drive backplane cables from the connector on the backplane.
76
Installing and removing system components

Table of Contents

Related product manuals