3 If connected, disconnect all the cables connected to the left expansion card riser.
4 If installed, remove the left expansion card riser.
5 Locate the Network Daughter Card (NDC) riser connector (on PCIe slot 2).
Steps
1 Hold the Network Daughter Card (NDC) riser by its edges and align the connector on the NDC riser with the connector on the
system.
NOTE: The NDC slot on the system board is keyed
dierently.
2
Insert the NDC riser until the card is fully seated.
3 Close the PCI retention rocker to lock the NDC riser.
Figure 58. Installing the NDC riser
1
NDC 2 PCI retention rocker
3 connector on the system board
Next steps
1 If removed, install the left expansion card riser.
2 Re-connect all the disconnected cables
3 Follow the procedure listed in the After working inside your system section.
Related links
Safety instructions
Before working inside your system
Removing the left or right expansion card riser
Installing the left or right expansion card riser