EasyManuals Logo

Dell Storage Center SCv2020 User Manual

Dell Storage Center SCv2020
110 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #49 background imageLoading...
Page #49 background image
d. Use the host operating system to assign IP addresses for each iSCSI port. The IP addresses must
match the subnets for each fault domain.
CAUTION: Correctly assign IP addresses to the HBAs or network adapters. Assigning IP
addresses to the wrong ports can cause connectivity issues.
NOTE: If using jumbo frames, they must be enabled and configured on all devices in the data
path, adapter ports, switches, and storage system.
e. If the host uses network adapters for iSCSI traffic, add the VMkernel ports to the iSCSI software
initiator.
f. Use the iSCSI cabling diagrams to cable the host servers to the switches. Connecting host servers
directly to the
storage system without using Ethernet switches is not supported.
Two iSCSI Networks with Dual 10 GbE 2–Port Storage Controllers
Use two iSCSI networks to prevent an unavailable port, switch, or storage controller from causing a loss
of connectivity between the host servers and a storage system with dual 10 GbE 2-port storage
controllers.
About this task
This configuration includes two fault domains, two iSCSI networks, and two Ethernet switches. The
storage controllers connect to each Ethernet switch using one iSCSI connection.
If a physical port or Ethernet switch becomes unavailable, the storage system is accessed from the
switch in the other fault domain.
If a storage controller becomes unavailable, the virtual ports on the offline storage controller move to
the physical ports on the other storage controller.
Steps
1. Connect each server to both iSCSI networks.
2. Connect fault domain 1 (shown in orange) to iSCSI network 1.
Storage controller 1: port 1 to Ethernet switch 1
Storage controller 2: port 1 to Ethernet switch 1
3. Connect fault domain 2 (shown in blue) to iSCSI network 2.
Storage controller 1: port 2 to Ethernet switch 2
Storage controller 2: port 2 to Ethernet switch 2
Connect the Front End
49

Table of Contents

Other manuals for Dell Storage Center SCv2020

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell Storage Center SCv2020 and is the answer not in the manual?

Dell Storage Center SCv2020 Specifications

General IconGeneral
Form Factor2U
RAID SupportRAID 0, 1, 5, 6, 10
ControllersDual Controllers
Host ConnectivityiSCSI, Fibre Channel
Product TypeStorage Array
Storage TypeSAN
Management SoftwareDell Storage Manager
ProcessorIntel Xeon
Maximum Raw Capacity480 TB
Power SupplyDual
ProtocolsiSCSI, Fibre Channel
Max Storage480 TB
Drive TypeSSD, HDD
Drive Types SupportedSSD
Operating Temperature10° to 35°C (50° to 95°F)
Host Interface8/16 Gb Fibre Channel, 10 Gb iSCSI
Host Port Speed8/16 Gb Fibre Channel, 10 Gb iSCSI