Chapter 3 Product Specifications
3-31
2. Counting up/Counting down
Maximum speed
Single axis: 1M PPS
Multi-axis interpolation: 1M PPS
Input
signal
STOP/RUN (automatic/manual switch)
Detector
X0.0+, X0.0-, X0.1+, X0.1-, X0.2+, X0.2-, X0.3+, X0.3-, X0.4, X0.5, X0.6, X0.7,
X0.10, X0.11, X0.12, X0.13, X0.14, X0.15, X1.0, X1.1, X1.2, X1.3, X1.4, X1.5
Output
Servo output
Y0.0+, Y0.0-, Y0.2+, Y0.2-, Y0.4+, Y0.4-, Y0.6+, Y0.6-, Y0.1+, Y0.1-, Y0.3+, Y0.3-,
Y0.5+, Y0.5-, Y0.7+, Y0.7-, Y0.8, Y0.9, Y0.10, Y0.11
External communication
Mini USB port
Memory card slot
Supports Micro SD card
The maximum capacity is 32 GB.
Number of basic
instructions
27
Number of applied
instructions
130
M-code
1. OX0~OX99 (motion subroutine/positioning program): M02 (The execution of the
program stops. (END))
2. M00~M01, M03~M101, and M103~M65535: The execution of the program
pauses. (WAIT) You can use them freely.
G-code
G0 (rapid positio
ning), G1 (linear interpolation), G2 (circular interpolation, clockwise),
G3 (circular interpolation, counterclockwise), G4 (dwell), G17 (XY plane selection),
G18 (ZX plane selection), G19 (YZ plane selection), G90 (absolute programming),
and G91 (incremental programming)
Description of the terminals
Terminal Description
Response
characteristic
X0.0+, X0.0-,
X0.1+, X0.1-,
X0.2+, X0.2-,
X0.3+, and
X0.3-
1. Differential input terminals.
2. The functions of the terminals:
Motion control: They are the PG input terminals for
axis 1~axis 4.
High-speed counter: X0.0+ and X0.0- are the
RESET input terminals for counter 0. X0.1+ and
X0.1- are the RESET input terminals for counter 1.
X0.2+ and X0.2- are the RESET input terminals for
counter 2 and counter 4. X0.3+ and X0.3- are the
RESET input terminals for counter 3 and counter 5.
High-speed capture: The terminals can function as
trigger signals for high-speed captures.
200 kHz 5 mA 5~24 V
X0.4, X0.5,
X0.6, and X0.7
1 Single/A/B-phase input terminals.
2 The functions of the terminals:
Motion control: They are the DOG input terminals
100 kHz (*1) 5 mA 24 V