EasyManua.ls Logo

Delta AHCPU560-EN2 Series - Vendor Specific Objects; Register (Class ID: 16#350)

Delta AHCPU560-EN2 Series
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EtherNet/IP Operation Manual
8-24
_8
Instance
Attribute
Name
Access
Rule
Data Type Values
Description
cannot be sent due to MAC layer errors
Carrier Sense Errors
UDINT 16#0
The number of times when no response
on the carrier sense or no resent during
the sending of the packets.
Frame Too Long
UDINT 16#0
The number of times when the lengh of
the received packet exceeds the upper
limit.
MAC Receive Errors
UDINT 16#0
The number of times when an error
occurs on the packet receiving due
to MAC layer error
16#0A
Interface Label
Get
SHORT_S
TRING
NA
Define the Ethernet port name
For example: AH10EN-5A When
Ethernet port is x2, the expression will
be 02 78 32.
Length USINT NA
The maximum length of the name is 16
characters.
Interface name
SHORT_S
TRING
NA
Use ASCII characters to name the
Ethernet port name.
1 Interface Flag Table
8.12 Vendor Specific Objects
8.12.1 X Register (Class ID: 16#350)
Service Code
Service Code Service Name
Support
Description
Class Attribute
Instance
Attribute
16#0E Get_Attribute_Single X V
Read one attribute
16#32 Read_Parameter X V Read Parameter
Bit (s) Name Description
0 Link Status
0 indicates an inactive link
1 indicates an active link
1 Half/Full Duplex
0 indicates half duplex
1 indicates full duplex
2-4 Negotiation Status
0Auto-negotiation in progress
1Auto-negotiation and speed detection failed
2Auto negotiation failed but detected speed
3Successfully negotiated speed and duplex
4Auto-negotiation not attempted. Forced speed and duplex.
5 Manual Setting Requires Reset shall be set to zero
6 Local Hardware Fault
0 indicates the interface detects no local hardware fault
1 indicates a local hardware fault is detected
7-31 Reserved 0

Table of Contents