EasyManua.ls Logo

Delta AHCPU560-EN2 Series - M Register (Class ID: 16#353); S Register (Class ID: 16#354)

Delta AHCPU560-EN2 Series
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter 8 CIP Object
8-27
8_
Instance
Attribute
Name
Access
Rule
Data
Type
Values Description
16#00
D0 Set
INT
16#00
D0 word register
16#01
D1
Set
INT 16#00
D1 word register
16#02~16#752E
D2~D29998 Set
INT 16#00
D2~D29998 word register
16# Max
DMax Set
INT 16#00
The maximum number of the
instance attribute is determined
by the sepecifiation of the
connected AH series PLC.
8.12.4 M Register (Class ID: 16#353)
Service Code
Service Code Service Name
Support
Description
Class Attribute
Instance
Attribute
16#0E Get_Attribute_Single X V
Read one attribute
16#10 Set_Attribute_Single X V
Write one attribute
16#32 Read_Parameter X V Read Parameter
16#33 Write_Parameter X V Write Parameter
Class
Class ID16#353
Instance
16#01Instance Attribute, Bit Register
When Instance = 1, the Class Attributes are listed below.
Instance Attribute
Name
Access
Rule
Data
Type
Values Description
16#00
M0 Set BOOL 16#00
M0 word register
16#01
M1
Set
BOOL
16#00
M1 word register
16#02~16#1FFE
M2~M8190 Set BOOL 16#00 M2~M8190 word register
16# Max
MMax Set BOOL 16#00
The maximum number of the
instance attribute is determined
by the sepecifiation of the
connected AH series PLC.
8.12.5 S Register (Class ID: 16#354)
Service Code
Service Code Service Name
Support
Description
Class Attribute
Instance
Attribute
16#0E Get_Attribute_Single X V
Read one attribute
16#10 Set_Attribute_Single X V
Write one attribute
16#32 Read_Parameter X V Read Parameter
16#33 Write_Parameter X V Write Parameter

Table of Contents