Chapter 3 Product Specifications
3-7
3_
AH Series Host Example of Calculating the number of CIP Connection:
Long Range Communication
Station A
( AHRTU-ETHN-5A)
Module
Configuration:
AH16AM10N-5A X2
AH16AN01T-5A X2
AH06XA-5A X 3
AH10SCM-5A X 2
Long Range Communication
Station B
Module
Configuration :
AH16AM10N-5A X 2
AH16AP11T-5A X 4
AH08DA-5A X 2
AH08AD-5A X 1
AS Series Host
CIP Connection Used
for Data Exchange: 5
AH Series Host
( Scanner )
Calculating CIP Connections:
1. Long Range Communication Station A: 1 ( RTU+DIO)+ 3 ( AI/O)+ 2 (SCM)=6
2. Long Range Communication Station B: 1 RTU DIO 3 ( AI/O) = 4 ( + )+
3. AS Series Host: 5 (Connection Used for Data Exchange)
=> Total of CIP Connection Used: 6+4 5 15= =
( AHRTU-ETHN-5A)