Chapter 6 Control Mode of Operation ASDA-A2
6-22 Revision February, 2017
Unit:
0.1 Hz
Range:
10 ~ 1000
Data Size:
16-bit
Format:
Decimal
Example:
150= 15 Hz
Settings:
The setting value of the first low-frequency vibration suppression. If P1-
26 is set to 0, then it will disable the first low-frequency filter.
P1-26
VSG1
Low-frequency Vibration Suppression Gain
(1)
Address: 0134H
0135H
Operational
Interface:
Panel / Software Communication
Related Section:
6.2.9
Default:
0
Control
Mode:
PT / PR
Unit:
-
Range:
0 ~ 9 (0: Disable the first low-frequency filter)
Data Size:
16-bit
Format:
Decimal
Settings:
The first low-frequency vibration suppression gain. The bigger value it
is, the better the position response will be. However, if the value is set
too big, the motor will not be able to smoothly operate. It is suggested
to set the value to 1.
P1-27
VSF2 Low-frequency Vibration Suppression (2)
Address: 0136H
0137H
Operational
Interface:
Panel / Software Communication
Related Section:
6.2.9
Default:
1000
Control
Mode:
PT / PR
Unit:
0.1 Hz
Range:
10 ~ 1000
Data Size:
16-bit
Format:
Decimal
Example:
150 = 15 Hz

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-A2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals