EasyManuals Logo
Home>Delta>Servo Drives>ASDA-A2 Series

Delta ASDA-A2 Series User Manual

Delta ASDA-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #178 background imageLoading...
Page #178 background image
ASDA-A2 Chapter 6 Control Mode of Operation
Revision February, 2017 6-23
Settings:
The setting value of the second low-frequency vibration suppression. If
P1-28 is set to 0, then it will disable the second low-frequency filter.
P1-28
VSG2 Low-frequency Vibration Suppression Gain (2)
Address: 0138H
0139H
Operational
Interface:
Panel / Software Communication
Related Section:
6.2.9
Default:
0
Control
Mode:
PT / PR
Unit:
-
Range:
0 ~ 9 (0: Disable the second low-frequency
filter)
Data Size:
16-bit
Format:
Decimal
Settings:
The second low-frequency vibration suppression gain. The bigger value
it is, the better the position response will be. However, if the value is set
too big, the motor will not be able to smoothly operate. It is suggested to
set the value to 1.

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-A2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals