EasyManuals Logo
Home>Delta>Servo Drives>ASDA-A2 Series

Delta ASDA-A2 Series User Manual

Delta ASDA-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #265 background imageLoading...
Page #265 background image
Chapter 8 Parameters ASDA-A2
8-14 Revision February, 2017
Alarm of Servo Drive
001:Over current
002:Over voltage
003:Under voltage (In default setting, the alarm occurs only when the
voltage is not enough in Servo ON status; In Servo ON status,
when it applies to power R, S, T, the alarm still will not be cleared.
Please refer to P2-66.)
004:Motor combination error (The drive corresponds to the wrong
motor)
005:Regeneration error
006:Over load
007:Over speed
008:Abnormal pulse command
009:Excessive deviation of position command
010:Reserved
011:Encoder error (The servo drive cannot connect to the encoder
because of disconnection or abnormal wiring)
012:Adjustment error
013:Emergency stop
014:Reverse limit error
015:Forward limit error
016:IGBT overheat

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-A2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals