ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-15
017:Abnormal EEPROM
018:Abnormal signal output
019:Serial communication error
020:Serial communication time out
021:Reserved
022:Main circuit power lack phase
023:Early warning for overload
024:Encoder initial magnetic field error (The magnetic field of the
encoder U,V, W signal is in error)
025:The internal of the encoder is in error. (The internal memory of
the encoder and the internal counter are in error)
026:Unreliable internal data of the encoder
027:Encoder reset error
028:The encoder is over voltage or the internal of the encoder is in
error
029:Gray code error
030:Motor crash error
031:Incorrect wiring of the motor power line U, V, W (Incorrect wiring
of the motor power line U, V, W, GND)
034:Internal communication of the encoder is in error
040:Excessive deviation of full closed-loop position control
041:Communication of CN5 is breakdown
042:Analog input voltage error
044:Warning of servo drive function overload
060:The absolute position is lost
061:Encoder under voltage
062: The multi-turn of absolute encoder overflows
068:Absolute data transmitted via I/O is in error
069:Wrong motor type
099:DSP firmware upgrade
Alarm of CANopen Communication
111:CANopen SDO receives buffer overflow
112:CANopen PDO receives buffer overflow
121:Index error occurs when accessing CANopen PDO

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-A2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals