ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-21
P0-10
CM2 Status Monitor Register 2
Address: 0014H
0015H
Operational
Interface
Panel / Software Communication
Related Section:
4.3.5
Default
-
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Decimal
Settings
The setting value which is set by P0-18 should be monitored via P0-10.
(Please refer to Chapter 7.2.1, Description of Monitoring variable for
the setting value.) Set P0-02 to 24, the panel displays VAR-2 first, and
then shows the content of P0-10.
P0-11
CM3 Status Monitor Register 3
Address: 0016H
0017H
Operational
Interface
Panel / Software Communication
Related Section:
4.3.5
Default
-
Control
Mode
ALL
Unit
-
Range
-
Data Size
32-bit
Format
Decimal
Settings
The setting value which is set by P0-19 should be monitored via P0-11.
(Please refer to Chapter 7.2.1, Description of Monitoring Variable for
the setting value.) Set P0-02 to 25, the panel displays VAR-3 first, and
then shows the content of P0-11.