Chapter 8 Parameters ASDA-A2
8-82 Revision February, 2017
P1-63 FRCT Friction Compensation
Address: 017EH
017FH
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
PTPRS
Unit
ms
Range
0 ~ 1000
Data Size
16-bit
Format
Decimal
Settings
Setup smoothing constant of friction compensation.
P1-64 PCCT
Analog Position Command: Activation
Control
Address: 0180H
0181H
Operational
Interface
Panel/Software Communication
Related Section: N/A
Default
0x00
Control
Mode
PT
Unit
--
Range
0 x00~ 0x11
Data Size
32-bit
Format
Hexadecimal
Settings
X:
0: Disable the function of position command which is issued by
analog
1: Enable the function of position command which is issued by
analog

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)