EasyManuals Logo

Delta ASDA-A2 Series User Manual

Delta ASDA-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #337 background imageLoading...
Page #337 background image
Chapter 8 Parameters ASDA-A2
8-86 Revision February, 2017
P1-73 FERR
Error Protection Range for Full-closed Loop
Control
Address: 0192H
0193H
Operational
Interface
Panel / Software Communication
Related Section:
P2-34
Default
30000
Control
Mode
PT
Unit
Pulse (based on the feedback of full-closed
loop)
Range
1 ~ (2
31
-1)
Data Size
32-bit
Format
Decimal
Settings
The protection is for excessive deviation between feedback position of
linear scale and the encoder. When the deviation is excessive, it might
result from the loose of connector or other mechanism problems.
P1-74
FCON Full-closed Loop Control of Linear Scale
Address: 0194H
0195H
Operational
Interface
Panel / Software Communication
Related Section: P1-46
Default
1000h
Control
Mode
PT
Unit
-
Range
0000h ~ 0x4122
Data Size
16-bit
Format
Hexadecimal
Settings

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals