EasyManuals Logo

Delta ASDA-A2 Series User Manual

Delta ASDA-A2 Series
721 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #354 background imageLoading...
Page #354 background image
ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-103
P2-26 DST Anti-interference Gain
Address: 0234H
0235H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
1
Range
0 ~ 1023 (0: disable this function)
Data Size
16-bit
Format
Decimal
Settings
Increasing the value of this parameter can increase the damping of speed
loop. It is suggested to set P2-26 equals to the value of P2-06. If users
desire to adjust P2-26, please follow the rules below.
1. In speed mode, increase the value of this parameter can reduce
speed overshoot.
2. In position mode, decrease the value of this parameter can reduce
position overshoot.
P2-27 GCC Gain Switching and Switching Selection
Address: 0236H
0237H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
0
Control
Mode
ALL
Unit
-
Range
0x0000 ~ 0x0018
Data Size
16-bit
Format
Hexadecimal

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals