ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-157
P4-18 COF4
Current Detector (W2 Phase) Offset
Adjustment
Address: 0424H
0425H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
0 ~ 32767
Data Size
16-bit
Format
Decimal
Settings
Manually adjust the hardware offset. The adjustment function needs to
be enabled by the setting of parameter P2-08. It is not suggested to
adjust the auxiliary adjustment. This parameter cannot be reset.
P4-19 TIGB
IGBT NTC Adjustment Detection Level
(cannot reset)
Address: 0426H
0427H
Operational
Interface
Panel / Software Communication
Related Section: -
Default
Factory default
Control
Mode
ALL
Unit
-
Range
1 ~ 4
Data Size
16-bit
Format
Decimal
Settings
Please cool down the drive to 25 Celsius degree when adjusting

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)

Related product manuals