ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-167
P5-12
AYD0
Data ArrayWindow #1 for Reading / Writing
Address: 0518H
0519H
Operational
Interface
Panel / Software Communication
Related Section:
7.2
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
Settings
Window #1 (Array[P5-11++])
When reading the parameter via panel, the value set by P5-11 will not
add 1, but the others will.
P5-13
AYD1 Data Array - Window #2 for Reading / Writing
Address: 051AH
051BH
Operational
Interface
Panel / Software Communication
Related Section:
7.2
Default
0
Control
Mode
ALL
Unit
-
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
Settings
Window #2 (Array[P5-11++])
When reading and writing the parameter via panel or communication,
the value set by P5-11 will add 1. Panel is write-protected.
P5-14 Reserved

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)