ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-169
P5-17 AXAU Axis Position - Auxiliary Encoder
Address: 0522H
0523H
Operational
Interface
Panel / Software Communication
Related Section:
7.3
Default
-
Control
Mode
ALL
Unit
Pulse number
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
Settings
Sends back: pulse counts of the auxiliary encoder (linear scale)
P5-18 AXPC Axis Position - Pulse Command
Address: 0524H
0525H
Operational
Interface
Panel / Software Communication
Related Section:
7.3
Default
-
Control
Mode
ALL
Unit
Pulse number
Range
-2147483648 ~ +2147483647
Data Size
32-bit
Format
Decimal
Settings
Sends back: pulse counts of pulse command

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)