ASDA-A2 Chapter 8 Parameters
Revision February, 2017 8-171
P5-21 AC1 Acceleration/Deceleration Time (Number #1)
Address: 052AH
052BH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
300
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-22 AC2 Acceleration/Deceleration Time (Number #2)
Address: 052CH
052DH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
500
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-23 AC3 Acceleration/Deceleration Time (Number #3)
Address: 052EH
052FH
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
600
Control
Mode
PR
Unit
ms

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)