Chapter 8 Parameters ASDA-A2
8-172 Revision February, 2017
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-24 AC4 Acceleration/Deceleration Time (Number #4)
Address: 0530H
0531H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
800
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.
P5-25 AC5 Acceleration/Deceleration Time (Number #5)
Address: 0532H
0533H
Operational
Interface
Panel / Software Communication
Related Section:
7.10
Default
900
Control
Mode
PR
Unit
ms
Range
1 ~ 65500
Data Size
16-bit
Format
Decimal
Settings
Please refer to P5-20 for the setting of acceleration/deceleration time in
PR mode.

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)