Pulse command can be input by the way of open-collector or Line driver. The maximum input pulse
of Line driver is 500 kpps and 200 kpps for open-collector.
C3-1: The source of pulse input is open-collector NPN equipment which applies the internal
power of the servo drive.
C3-2: The source of pulse input is open-collector PNP equipment which applies the internal
power of the servo drive.
NOTE
Resistor of 1K(1w) has to be connected.

Table of Contents

Other manuals for Delta ASDA-A2 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-A2 Series and is the answer not in the manual?

Delta ASDA-A2 Series Specifications

General IconGeneral
Enclosure RatingIP20
Control ModePosition, Speed, Torque
Communication InterfaceRS-485, CANopen
ProtectionOvercurrent, Overvoltage, Undervoltage, Overload, Overtemperature, Encoder error
Operating Temperature0°C to 55°C
Storage Temperature-20°C to 65°C
Humidity20% to 90% RH (non-condensing)
Altitude1000m max
Cooling MethodNatural cooling or forced air cooling
Encoder Feedback20-bit incremental encoder (standard), 17-bit absolute encoder (optional)