Chapter 9 Specification C2000
9-5
9-3 575V Series
Frame Size A B
Model VFD-_ _ _ C53A-21 015 022 037 055 075 110 150
*Output Rating
Light Duty
Rated Output Capacity [kVA] 3 4.3 6.7 9.9 12.1 18.6 24.1
Rated Output Current [A] 3 4.3 6.7 9.9 12.1 18.7 24.2
Applicable Motor Output [kW] 1.5 2.2 3.7 5.5 7.5 11 15
Applicable Motor Output [HP] 2 3 5 7.5 10 15 20
Normal Duty
Rated Output Capacity [kVA] 2.5 3.6 5.5 8.2 10 15.4 19.9
Rated Output Current [A] 2.5 3.6 5.5 8.2 10 15.5 20
Applicable Motor Output [kW] 0.75 1.5 2.2 3.7 5.5 7.5 11
Applicable Motor Output [HP] 1 2 3 5 7.5 10 15
Heavy Duty
Rated Output Capacity [kVA] 2.1 3 4.6 6.9 8.3 12.9 16.7
Rated Output Current [A] 2.1 3 4.6 6.9 8.3 13 16.8
Applicable Motor Output [kW] 0.75 1.5 2.2 3.7 3.7 7.5 7.5
Applicable Motor Output [HP] 1 2 3 5 5 10 10
Carrier Frequency [kHz] 2~15 (Default: 6)
Input Rating
Input Current [A]
Light Duty 3.8 5.4 10.4 14.9 16.9 21.3 26.3
Normal Duty 3.1 4.5 7.2 12.3 15 18 22.8
Heavy Duty 2.6 3.8 5.8 10.7 12.5 16.9 19.7
Rated Voltage / Frequency 3-phase AC 525 ~ 600 V ( -15%~+10%), 50/60 Hz
Operating Voltage Range 446~660V
AC
Frequency Tolerance 47~63Hz
Efficiency [%] 97 98
Power Factor >0.98
Drive Weight [Kg] 3 ± 0.3 4.8 ± 1
Cooling Method Natural cooling Fan cooling
Braking Chopper Frame A~B: Built-in
DC choke Frame A~B: Optional
EMC Filter Frame A~B: Optional
Table 9-4
NOTE
* Parameter 00-16; available load modes: Light Duty (LD), Normal Duty (ND) and Heavy Duty (HD); default setting is LD mode