Chapter 12 Description of Parameter SettingsC2000
12.1-02-7
Settings Functions Descriptions
35
Enable single-point
position control
ON: the AC motor drive executes internal single-point position
control according to the setting for Pr.10-19. This function is
valid in FOCPG mode only.
36
Enable multi-step
position learning function
(valid at stop)
ON/OFF: the drive uses the multi-function inputs 1
4 ON/OFF
status to find the corresponding multi-step positions and writes
the current motor position into the corresponding multi-step
position.