1) Pickup
CD
Tilt Sensor Balance.
Caution: The spare Pickup (SOAD90A) has been adjusted and needs no adjustment.
Measurement Point
Adjust
Mode Disk
TEO
Tilt
Sensor
Playback B
MTD-04
Adjust Screw
Pause
Chapter
7-8
Measuring Instrument Adjust
to
Oscilloscope Kick Pulse Amplitude Maximum
1.
Connect Oscilloscope to "TEO".
2.
Playback chapter
7-8
of Test
LO
MTD-04 (CAV)B, and set the unit to pause mode.
3.
Adjust tilt sensor adjustment screw so that kick pulse (Figure 10) amplitude reads maximum.
Grating
Hole
Tilt
Sensor Adjustment Screw
[Pickup Reverse Side)
Kick
Pulse
!Oscilloscope
Setting!
Figure 9
Maximum
Amplitude
e VOLT: 500mV/div e SWEEP : 5msec/div Figure 10
@Adjustment screw lock paint after the Pickup adjustment lock the
screw with
lock paint.
1.
Screw to be locked
(1) Grating Hole
2.
Lock Bond
(1) Name: Three bond