6.3 Cooling System Service and Maintenance
0297 4985 1
BFM 1013E
1013 E
Short engine
z With external cooling systems in accordance
with the specifications of the manufacturer.
z Loosen vent plug position 2 and sealing plug
position 3.
z Add coolant up to the maximum marking or
filler limit (heater valve of the system must be
opened – if fitted).
z Tighten vent plug position 2 + sealing plug
position 3.
z Close radiator cap position 1.
z Start engine and warm up until thermostat
opens.
z Switch off engine.
z Check coolant level when the engine is cold
and top up as required.
z Close the radiator sealing plug position 1.
9682en_K06.p65 17.11.2008, 12:2169