ENGLISCH • Kapitel 6 • Seite 74
6
© 2002
6.4.4 Dry Type Air Cleaner
Dust Discharge Valve
Filter Cartridge
z Empty dust discharge valve 1 by pressing
apart lips of discharge slot as indicated
by arrows.
z Clean discharge slot from time to time.
z Remove any caked dirt by pressing
together the upper section of the valve.
z Undo clip fasteners 1.
z Take off hood 2 and remove cartridge 3.
z Clean cartridge (replace at least once a
year).
z Clean cartridge 3:
Blow out from inside out with dry com-
pressed air (max. 5 bar), or
in difficult cases, tap out, taking care
not to damage the cartridge, or
wash according to manufacturer’s
instructions.
z Check paper filter (light showing through)
and gaskets for damage. Replace if
necessary.
z After five air cleaner services or after
two years at the latest, replace safety
cartridge 4 (never clean).
To do so:
Undo hex. nut 5 and remove cartridge 4.
Install new cartridge, insert and tighten
hex. nut.
z Install cartridge 3, replace hood 2 and do
up clip fasteners.
Never clean filter cartridge
with gasoline or hot fluids.