SIRIUS®
9.2 Documentation version history
Revision number: 850
Last modified: Fri 13 Nov 2015, 09:22
Version
Date
[dd.mm.yyyy] Notes
1.0.0 26.11.2011
initial revision
changes to orig. wiring image: counter voltage is 12V (instead of 15V)
changes to orig. wiring image: CAN voltage is 15V (instead of 12V)
1.0.1 04.12.2011
Added bridge ranges of MULTI8
corrected Illustration 62: SIRIUS-MULTI8 pin-out DSUB-15 (pin 12)
updated/corrected module specifications
updated Illustration 53: SIRIUS chassis: connectors on the back side
removed STG module
corrected captions of: Illustration 61: SIRIUS-MULTI8 and Illustration 63: SIRIUS-HV8
1.0.2 04.12.2011
Added bridge connection diagrams
1.0.3 16.01.2012
Corrected text of Bridge measurement tables
Corrected typical power consumption: Table 7: SIRIUS-ACC8 specifications
Added chapter about 'Isolation'
1.0.4 12.03.2012
Added 3.3.1.1 Troubleshooting
Corrected module overview: MULTI module does not have digital output
1.1.0 01.12.2012
Intermediate version for VOLVO - only STG modules!
added STG-M pin-out
added STG8 modules
major changes to chapter 5 SIRIUS Hardware
added new chapter 6.1 Wireless Connection#
updated to DEWESoftX 7.1 (screenshots, installation info)
1.1.1 21.12.2012
Major changes
added ACC, HV, MULTI, STGM
added STG LEMO10
STG-LEMO7: pinnings were wrong
updated specifications
1.1.2 15.03.2013
Added STGM+
4.7 DS-BP2: Battery Pack: added weight
ACC+: added connector article numbers
SNR → Typ. SNR
1.1.3 16.03.2013
STGM: Typ. SNR for 10 V range (Dual Core) is now 125dB (was 119dB).
Corrected caption of Illustration 59 (was back side)
added: 4.6.3.2 S-BOX: GPS connector
removed Excitation Voltage from: Table 6: SIRIUS-ACC8 specifications
changed counter specification tables for ACC+ and STGM+ to show values per module,
STGM+: removed digital output from specs table
1.1.4 20.06.2013
STG specifications enhanced
Analogue-out specifications updated
Page 164/166 www.dewesoft.com Doc-Version: 1.4.2
DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft® DEWESoft®
measurement innovation measurement innovation measurement innovation measurement innovation measurement innovation measurement innovation measurement innovation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DEWESOFT SIRIUS and is the answer not in the manual?

DEWESOFT SIRIUS Specifications

General IconGeneral
Resolution24-bit
IsolationChannel-to-channel and channel-to-ground
InterfaceUSB
SoftwareDewesoftX data acquisition software
BandwidthDC to 50 kHz (depending on module type)
Humiditynon-condensing
Analog InputsVoltage, IEPE, Charge, Current, Strain Gage, Thermocouple, RTD, Resistance, LVDT, Bridge