EasyManua.ls Logo

Digi XBEE-PRO S3B - M1 (PWM1 Duty Cycle); Associate LED Blink Time); RP (RSSI PWM Timer); IO Sampling Commands

Digi XBEE-PRO S3B
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT commands I/O sampling commands
XBee®-PRO 900HP/XSC RF Modules
103
M1 (PWM1 Duty Cycle)
The duty cycle of the PWM1 line (pin 7).
Use the P1 command to configure the line as a PWM output.
Parameter range
0 - 0x3FF
Default
0
LT (Associate LED Blink Time)
Set or read the Associate LED blink time. If you use the D5 command to enable the Associate LED
functionality (DIO5/Associate pin), this value determines the on and off blink times for the LED.
If LT = 0, the device uses the default blink rate: 500 ms for a sleep coordinator, 250ms for all other
nodes.
For all other LT values, the firmware measures LT in 10 ms increments.
Parameter range
0x14 - 0xFF (x 10 ms)
Default
0
RP (RSSI PWM Timer)
The PWM timer expiration in 0.1 seconds. RP sets the duration of pulse width modulation (PWM) signal
output on the RSSI pin.
When RP = 0xFF, the output is always on.
Parameter range
0 - 0xFF (x 100 ms)
Default
0x28 (four seconds)
I/O sampling commands
The following AT commands configure I/O sampling parameters.
AV (Analog Voltage Reference)
The analog voltage reference used for A/D sampling.
Parameter range
0 - 2
0, 1