AT commands Command mode options
XBee®-PRO 900HP/XSC RF Modules
110
Default
0xBB8
MS (Missed Sync Messages)
Reads the number of sleep or wake cycles since the device received a sync message.
Supported in the mesh firmware variant only.
Parameter range
[read-only]
Default
0
SQ (Missed Sleep Sync Count)
Counts the number of sleep cycles in which the device does not receive a sleep sync.
Set the value to 0 to reset this value.
When the value reaches 0xFFFF it does not increment anymore.
Parameter range
0 - 0xFFFF
Default
0
Command mode options
The following commands are Command mode option commands.
CC (Command Character)
Sets or displays the character the device uses between guard times of the Command mode sequence.
The Command mode sequence causes the device to enter Command mode (from Idle mode).
Note We recommend using the a value within the rage of 0x20 - 0x7F as those are ASCII characters.
Parameter range
0 - 0xFF
Recommended: 0x20 - 0x7F (ASCII)
Default
0x2B (the ASCII plus character:+)
CN (Exit Command Mode)
Immediately exits Command Mode and applies pending changes.

Table of Contents

Other manuals for Digi XBEE-PRO S3B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBEE-PRO S3B and is the answer not in the manual?

Digi XBEE-PRO S3B Specifications

General IconGeneral
BrandDigi
ModelXBEE-PRO S3B
CategoryControl Unit
LanguageEnglish

Related product manuals