AT commands Diagnostic commands
XBee®-PRO 900HP/XSC RF Modules
82
TR (Transmission Failure Count)
This count increments whenever a MAC transmission attempt exhausts all MAC retries without ever
receiving a MAC acknowledgment message from the destination node. Once the number reaches
0xFFFF, it does not count further events.
To reset the counter to any 16-bit value, append a hexadecimal parameter to the command.
Parameter range
0 - 0xFFFF
Default
0
UA (MAC Unicast Transmission Count)
This count increments whenever a MAC unicast transmission occurs that requests an ACK. Once the
number reaches 0xFFFF, it does not count further events.
You can reset the counter to any 16-bit unsigned value by appending a hexadecimal parameter to the
command.
Parameter range
0 - 0xFFFF
Default
0
%H (MAC Unicast One Hop Time)
The MAC unicast one hop time timeout in milliseconds. If you change the MAC parameters it can
change this value.
Parameter range
[read-only]
Default
0xCF
0x267
%8 (MAC Broadcast One Hop Time)
The MAC broadcast one hop time timeout in milliseconds. If you change MAC parameters, it can
change this value.
Parameter range
[read-only]
Default
0x1BE

Table of Contents

Other manuals for Digi XBEE-PRO S3B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi XBEE-PRO S3B and is the answer not in the manual?

Digi XBEE-PRO S3B Specifications

General IconGeneral
BrandDigi
ModelXBEE-PRO S3B
CategoryControl Unit
LanguageEnglish

Related product manuals