EasyManua.ls Logo

Digi XBEE-PRO S3B - Serial Interfacing Commands

Digi XBEE-PRO S3B
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AT commands Security commands
XBee®-PRO 900HP/XSC RF Modules
91
Security commands
The following AT commands are security commands.
EE (Security Enable)
Enables or disables 128-bit Advanced Encryption Standard (AES) encryption.
Set this command parameter the same on all devices in a network.
Parameter range
0 - 1
Parameter Description
0 Encryption Disabled
1 Encryption Enabled
Default
0
KY (AES Encryption Key)
Sets the 16-byte network security key value that the device uses for encryption and decryption.
This command is write-only. If you attempt to read KY, the device returns an OK status.
Set this command parameter the same on all devices in a network.
The value passes in as hex characters when you set it from AT command mode, and as binary bytes
when you set it in APImode.
Parameter range
128-bit value
Default
N/A
Serial interfacing commands
The following AT commands are serial interfacing commands.
BD (Baud Rate)
Values from 0 - 8 select preset standard rates.
Values at 0x39 and above select the actual baud rate if the host supports it.
Parameter range
Standard baud rates: 0x0 - 0x8
Non-standard baud rates: 0x100 to 0x6ACFC0