AT commands Diagnostic - sleep status/timing commands
XBee®-PRO 900HP/XSC RF Modules
109
SS (Sleep Status)
Queries a number of Boolean values that describe the device's status.
Bit Description
0 This bit is true when the network is in its wake state.
1 This bit is true if the node currently acts as a network sleep coordinator.
2 This bit is true if the node ever receives a valid sync message after it powers on.
3 This bit is true if the node receives a sync message in the current wake cycle.
4 This bit is true if you alter the sleep settings on the device so that the node
nominates itself and sends a sync message with the new settings at the beginning of
the next wake cycle.
5
This bit is true if you request that the node nominate itself as the sleep coordinator
using the Commissioning Pushbutton or the CB2 command.
6 This bit is true if the node is currently in deployment mode.
Allotherbits Reserved. Ignore all non-documented bits.
Parameter range
[read-only]
Default
0x40
OS (Operating Sleep Time)
Reads the current network sleep time that the device is synchronized to, in units of 10 milliseconds. If
the device has not been synchronized, then OS returns the value of SP.
If the device synchronizes with a sleeping router network, OS may differ from SP.
Parameter range
[read-only]
Default
0x12C
OW (Operating Wake Time)
Reads the current network wake time that a device is synchronized to, in 1 ms units.
If the device has not been synchronized, then OW returns the value of ST.
If the device synchronizes with a sleeping router network, OW may differ from ST.
Parameter range
[read-only]