Configuration and commands Command mode options
XBee®-PRO 900HP/XSC RF Modules
206
Recommended: 0x20 - 0x7F (ASCII)
Default
0x2B (ASCII +)
Bytes returned
1
CD (DO3 Configuration)
Selects or reads the behavior of the DO3/RX LED line.
Parameter range
0 - 3
Parameter Configuration
0 RXLED
1 Default high
2 Default low
3 Reserved
4 Assert only when you have sent the packet addressed to the device.
Default
0
Bytes returned
1
CN (Exit Command Mode)
Makes the device exit Command mode.
Binary command
0x09 (9 decimal)
Parameter range
N/A
Default
N/A
Bytes returned
N/A