EasyManua.ls Logo

Digi XBEE-PRO S3B - General Purpose Flash Memory Commands; PLATFORMINFOREQUEST (0 X00); PLATFORMINFO (0 X80)

Digi XBEE-PRO S3B
269 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
General Purpose Flash Memory General Purpose Flash Memory commands
XBee®-PRO 900HP/XSC RF Modules
174
Byte offset in
payload
Number of
bytes Fieldname General field description
0 1 GPM_CMD_ID This field is the same as the
request field.
1 1 GPM_STATUS Status indicating whether the
command was successful.
2 2* GPM_BLOCK_NUM The block number addressed in
the GPM.
4 2* GPM_START_INDEX The byte index within the
addressed GPM block.
6 2* GPM_NUM_BYTES The number of bytes in the GPM_
DATA field.
8 varies GPM_DATA
* Specify multi-byte parameters with big-endian byte ordering.
General Purpose Flash Memory commands
This section provides information about commands that interact with GPM:
PLATFORM_INFO_REQUEST (0x00)
A PLATFORM_INFO_REQUEST frame can be sent to query details of the GPM structure.
Field name Command-specific description
GPM_CMD_ID Should be set to PLATFORM_INFO_REQUEST (0x00).
GPM_OPTIONS This field is unused for this command. Set to 0.
GPM_BLOCK_NUM This field is unused for this command. Set to 0.
GPM_START_INDEX This field is unused for this command. Set to 0.
GPM_NUM_BYTES This field is unused for this command. Set to 0.
GPM_DATA No data bytes should be specified for this command.
PLATFORM_INFO (0x80)
When a PLATFORM_INFO_REQUEST command request has been unicast to a node, that node sends a
response in the following format to the source endpoint specified in the requesting frame.
Field name Command-specific description
GPM_CMD_ID Should be set to PLATFORM_INFO (0x80).

Table of Contents

Other manuals for Digi XBEE-PRO S3B

Related product manuals