JT100/JT100 All Terrain Operator’s Manual Systems and Equipment - 151
Electric Strike System
Electric Strike System
Any time you drill in an electric jobsite, electric strike system must be properly set up, tested, and used.
Drill operator and tracker operator must wear protective boots, and the drill operator must have protective
gloves within reach, all meeting the following standards:
Boots must have high tops and meet the electric hazard protection requirements of ASTM F2413 or
ASTM F1117when tested at 14,000 volts. Tuck legs of pants completely inside boots.
Gloves must have 17,000 AC maximum use voltage, according to ASTM specification D120.
If working around higher voltage, use gloves and boots with appropriately higher ratings.
Read and follow “Electric Jobsite Precautions” on page 85. Review safety procedures before each job.
If an electric strike occurs, immediately contact your local Ditch Witch
®
dealer to have the electric strike
system tested.
FCC Statement
The Electric Strike System has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the
FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, can cause harmful interference to radio communications. Operation of this equipment in a
residential area could cause harmful interference which the user will be required to correct at his own expense.
Changes or modifications not expressly approved in writing by The Charles Machine Works, Inc. may void the user's authority to
operate this equipment.
NOTICE: The strike system does not prevent electric strikes or detect strikes before they occur. If
alarms are activated, a strike has already occurred and equipment is electrified.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ditch Witch JT100 and is the answer not in the manual?

Ditch Witch JT100 Specifications

General IconGeneral
BrandDitch Witch
ModelJT100
CategoryConstruction Equipment
LanguageEnglish

Related product manuals