Service - 228 JT100/JT100 All Terrain Operator’s Manual
2000 Hour
2000 Hour
Drilling Unit
Change JT Fluid Pump Oil
Change fluid pump oil every 2000 hours.
To change:
1. Drain oil at plug (3). Ensure that the drain
plug is cleaned of debris before reinstalling.
2. Add 12 qt (11.3 L) of PTF at fill (1) until oil
level is at middle of sight tube (2).
Location Task Notes
DRILLING
UNIT
Change JT fluid pump oil PTF
Change engine coolant DEAC
Replace crankcase ventilation filter
Check seatbelt and seatbelt mounting hardware
LOADER/
DRIVER
Change anchor driver gearbox oil MPL