Ditch Witch JT100 - Emergency Exit; Override Box

Ditch Witch JT100
268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JT100/JT100 All Terrain Operator’s Manual Controls - 65
Emergency Exit
Emergency Exit
Push rear window out and exit to rear of cab.
Override Box
1. Drive override connector
2. Drill override connector
3. Drilling fluid flow override switch
4. Thrust/pullback or right track override switch
5. Rotation or left track override switch
Item Description Notes
1. Drive override
connector
Allows drive function override
when box is attached.
Use switches 4 and 5 to control
tracks.
2. Drill override connector Allows drill function override
when box is attached.
Use switches 3, 4 and 5 to control drill
functions.
3. Drilling fluid flow
override switch
To turn fluid on, move right.
To turn fluid off, move left.
Connect to drill connector (2) to
control fluid flow.