EasyManua.ls Logo

Ditch Witch JT100 - Pipe-By-Pipe Bend Limits Chart

Ditch Witch JT100
268 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
JT100/JT100 All Terrain Operator’s Manual Prepare - 89
Plan Bore Path
Bend Radius
JT100 Power Pipe
®
HD drill pipes have a tested
minimum bend radius of 205’ (62.5 m). This means
that a 90° bend in the bore path:
has a radius (A) of 205’ (62.5 m)
requires approximately 325’ (99 m) of drill pipe
(B).
JT100 Power Pipe Forged drill pipes have a tested
minimum bend radius of 197’ (60 m). This means that
a 90° bend in the bore path:
has a radius (A) of 197’ (60 m)
requires approximately 310’ (94.5 m) of drill
pipe (B).
JT100 All Terrain drill pipes have a tested minimum bend radius of 205’ (62.5). This means that a 90° bend
in the bore path:
has a radius (A) of 205’ (62.5 m)
requires approximately 325’ (99 m) of drill pipe (B).
NOTICE: Bending drill pipe more sharply than recommended will damage the pipe and cause failure
over time.
If bend radius is reduced, drill pipe life is reduced.
If bend radius is increased, drill pipe life is increased.
IMPORTANT: Use the charts on the next page to keep bends within safe limits.