27
No deco end – alarm triggered at the moment of termination of the no-decompression time
Deco stop end - alarm triggered at the moment of termination of the decompression stop
Gas switch reminder – alarm triigered at the optimal gas switch depth
Gas switch done - alarm triggered at the moment when the gas switch is done
Depth – you can use three different depth alarms (alarms are activated by each exceeding of the
depth by descent).
Time – you can use three different time alarms
CCR setup
This part of the manual pertains only to Freedoms with a CCR license.
For setting the parameters of the CCR mode, go to the Setup/CCR setup menu. Setup is identical for
diving in the directly measured partial pressure mode (Measured CCR) and in the constant ppO2
mode (Fixed CCR). In the “Number of sensors” item, set the number of sensors connected to the
Freedom computer. According to the setting, the corresponding number of fields for displaying the
measured ppO2 are displayed in the diving mode. The setting of the number of sensors is irrelevant
for the Fixed CCR mode.
With the “Diluent” item, set the composition of the utilized diluent for your planned dive. WARNING!
If you set a different diluent than the one you are actually using, the Freedom computer will actually
calculate the wrong decompression and CNS toxicity calculation. This situation can cause serious
injury or death.