1802-065-D-10-14
8
1.1.2 Install Enclosure
1. Mount the enclosure using the mounting holes provided
in the corners (see sections 1.2 and 1.3 for your chosen
model dimensions). Be sure that mounting screws or nuts
(Not supplied) do not protrude into the enclosure where
they could cause a short on the back of the circuit board.
Make any necessary conduit connections through the back
or bottom of the enclosure using the existing conduit
knock-outs. DO NOT make any new conduit holes in the
enclosure.
2. Route all wiring through conduit or mounting post (not
supplied) into enclosure.
3. Clean out the enclosure. Make sure that all dirt, metal
and/or wood debris is removed.
4. Re-install components back into the enclosure (Reverse
section 1.1.1 steps on previous page). Use the wiring
schematics in the back of this manual to help re-install the
components if necessary. DO NOT apply any power at this
time.
There are 2 different styles of the 1802 telephone entry system -
surface and flush mount. The illustrations below show typical
installations but specific installations can vary from this.
There are different styles
of DoorKing mounting
posts. All mounting posts
need the adapter plate to
mount the 1802. Surface
mount models ONLY.
Use hardware supplied with
mounting post to secure
adapter plate to post.
Use hardware supplied with
adapter plate to secure
enclosure to adapter plate.
Use appropriate
hardware to secure
enclosure to the wall
(not supplied).
Mount
ON
a Surface
(See section 1.2).
Mount
IN
a Surface
(See section 1.3).
Mount to a Mounting Post
M
ou
nting Screws
(Not supplied)
Examples of conduit runs that may be used, depending on how
you choose to run the wiring. Some installations will allow the
conduit to be run outside the wall and connect to the bottom of the
enclosure but this is generally NOT recommended.
Run all wires
inside post.
Conduit run
to junction box
Conduit
sweep run
Wall
D
O
O
R
K
I
N
G
®
,
I
N
C
.
M
fg
.
i
n U
.
S.
A
.
A
c
c
es
s
C
on
t
rol
So
l
u
t
i
o
n
s
S
i
n
c
e
194
8
T
h
i
s
p
r
o
d
u
c
t
i
s
m
a
n
u
f
a
c
t
ured
u
n
d
e
r
o
n
e
o
r
m
or
e
o
f
t
h
e
f
ol
l
owi
n
g
U
.
S.
Pa
t
e
n
t
s
.
O
TH
ER
PA
T
E
N
T
S
PE
ND
I
NG
D
O
O
R
K
I
N
G I
N
C
.,
I
N
GL
E
WO
O
D
CA
Pa
t
e
n
t
N
o.
D
a
t
e
P
at
e
n
t
No.
D
a
t
e
DOORKING
Inglewood, Ca 90301
Model # 1800 Series
Serial #
Complies F.C.C. Part 68
F.C.C. Registration #
DUF6VT-12874-OT-T
Ringer Equiv. 0.0A
Jack USOC RJ11C or W
ACCESS CONTROL
SYSTEM UNITS
CONFORMS TO UL STD 294
OUTDOOR USE / WET
Knock-ou
ts
Knock-ou
ts
Mounting Screws
(Supplied)
Wall
Rough-In
B
ox
Flush Mount
Enclosure
Adapter
Plat
e
Surf
ace
Mount
Enclosur
e
Surface
Moun
t
Enc
losure