RESTRICTIONS AND WARNINGS
Install The Gate Operator Only If:
• The operator is appropriate for the usage Class of the application.
• All exposed pinch points are eliminated or guarded.
• This operator is intended for installation only on swing gates used to control vehicular traffic.
Pedestrians must be provided with a separate access opening.
• The gate must be installed in a location so that sufficient clearance is provided between the
gate and adjacent structures when opening and closing to reduce the risk of entrapment (see
diagram). Swinging gates should not open into public access areas.
• The gate must be properly installed and work freely in both directions prior to the installation
of the gate operator. Do not over-tighten the operator clutch to compensate for a damaged
gate.
• Controls must be far enough from the gate so that the user is prevented from coming in
contact with the gate while operating the controls. Outdoor or easily accessible controls
should have a security feature to prevent unauthorized use.
• All warning signs and placards must be installed where visible in the area of the gate.
Pedestrian Access
Roadway
The gate must be installed in a location so that
enough clearance is supplied between the gate and
adjacent structures when opening and closing to
reduce the risk of entrapment. Swinging gates shall
not open into public access areas.
UL 325 56.8.4.c
If less than 16", entrapment
protection in this area is required.
ASTM F2200 7.1.1.2
Fence
FenceGate Gate
Pilaster
Roadway
Gate
Roadway
Gate
Hinge mounted on corner
of pilaster eliminates
entrapment area.
PilasterPilaster
If greater than 4", entrapment
protection in this area is
required.
ASTM F2200 7.1.1.1
If greater than 16", entrapment
protection in this area is not
required.
ASTM F2200 7.1.1.2
The operator is intended for
installation only on gates used
for vehicles. Pedestrians must
be supplied with a separate
opening.
UL 325 56.8.4.b
Page 6