KYPD IN / KYPD OUT Connections
• KYPD IN (Keypad In): Receives and transmits data to the panel Keypad bus/AX‑
Bus.
• KYPD OUT (Keypad Out): Receives and transmits data out to other keypad(s) or
module(s). Install a dual‑connector harness to allow connection to other devices
up to the maximum number of devices supported.
When the 734 is powered from 24VDC, do not connect devices to KYPD OUT header.
Status LEDs
The 734 board contains three status LEDs.
• The Red LED turns on for the same duration as the door strike relay.
• The Yellow LED turns on for one second to indicate receipt of a valid Wiegand
input.