22 734 Installation and Programming Guide | Digital Monitoring Products, Inc.
Zone 3 REX Strike Time
Enter the number of REX seconds to elapse. The range
is5to 250 seconds. Press any select key or area to enter the
number of seconds. The default is 5 seconds.
Activate Onboard Speaker
Select YES to enable the onboard piezo for local
annunciation, such as alarm and trouble annunciations. Select
NO to turn the speaker o for all operations. This does not
aect remote annunciator open collector (RA) operation. The
default is NO.
Card Formats
Select DMP to allow credentials that use a 26‑45bit data
string. The menu advances to REQUIRE SITE.
Select CUSTOM to disable DMP format and program slots 1‑8
as needed. The menu advances to FORMAT NO.
Select ANY to allow all Wiegand card reads to activate the
door strike relay. The door strike relay is activated for the
length of time programmed in ZN3 REX TIME. No user code
information is sent to the panel. The menu advances to NO
COMM WITH PNL.
The default card format is DMP.
ZN 3 REX STRIKE
TIME: 5
ACTIVATE ONBOARD
SPEAKER? NO YES
CARD FORMATS
DMP CUSTOM ANY