XR500/XR100 User’s Guide 15Arming and Disarming
Key Fob Disarming
Press and hold the key fob button programmed for Disarming
or the Toggle arm/disarm button. The Green LED two-second
acknowledgement light indicates All System Off.
Area System Arming Operation
Area Assignment: Your security system has been set up into
separate areas. The number of areas and their names are listed on
the table in System Setup.
Arming the Area System
1. Press the COMMAND key until ARM DISARM is displayed.
2. Select ARM to arm the system.
3. Enter your user code if required. The keypad displays
ALL? NO YES.
4. Select NO to arm only selected areas. Go to step 5. Select
YES to arm all areas authorized for your user code. Go to
step 6.
5. If you selected NO in step 4, the display begins to list each
area to which you have access followed by NO YES.
Example: OFFICE NO YES
5a. Select YES for each area you want to arm.
5b. Select NO for each area you do not want to arm.
6. The system displays any bypassed zones or faulted 24-hour
or Priority zones. A faulted Priority zone cannot be armed.
7. At this point you can force arm or bypass any faulted zones.
A zone that is force armed is restored into the system if it later
returns to normal. A zone that is bypassed remains bypassed
until the system is disarmed. See steps 7a through 7d.
7a. If a problem exists on a zone, the zone name and
problem is shown followed by: OKAY BYPASS STOP.
7b. Select OKAY to force arm the faulted zone.
7c. Select BYPASS to bypass all faulted zones being
displayed.
Note: 24-hour zones cannot be bypassed.
7d. Select STOP to stop the system from arming. Correct
the zone problem(s) and return to step 1.
Your system may be programmed to require a user code
that has authorization to force arm or bypass a faulted
zone. To force arm or bypass a faulted zone, the system
asks you to enter a user code.
8. The display reads SYSTEM ON if at least one area in the
system is armed, and ALL SYSTEM ON if all areas in the
system are armed.
Note: Your system may be pre-programmed at installation
for the Instant Arming option.
9. The keypad next displays EXIT: ## INSTANT and begins to
count down the number of seconds remaining for you to
exit. When the delay expires, the exit zones are armed.
10. You can select INSTANT while EXIT: ## INSTANT is displayed
to immediately arm all exit zones and make them instant.
The keypad displays INSTANT.