28 XR500/XR100 User’s Guide User Menu
Browser Feature
If you are unsure of the zone number or description, refer to
Appendix B at the back of this guide for a diagram showing you
how to use the built-in Zone Monitor browser.
System Status
Displays the current condition of internal system hardware.
System Status shows the panel condition of AC power, battery
power, and optional panel tamper. When System Status is selected,
each monitor displays followed by OKAY or TRBL (Trouble) to
indicate the current condition.
Using the System Status Function
1. Access the User Menu.
2. Press COMMAND until SYSTEM STATUS? displays.
3. Press any Select key. The display starts listing each system
monitor and status.
For example: AC POWER - OKAY
Below are the System Monitor displays:
Keypad Display What it monitors
AC POWER AC power
BATTERY Battery power
TAMPER Panel box tamper
These are followed by either OKAY or TRBL (trouble).
If TRBL displays, call the service department for assistance.
4. The system then displays its rmware version, the panel
mode, and then exits the User Menu.
For example: VER_118_1/20/07 MODEL XR500
System Test
System Test is used to test the battery, alarm bell or siren, and
communi cation to a central station. The System Test function
begins automatically as soon as you select it.
Note: If an area is in an armed state, the system test will not
operate.
Using the System Test Function
1. Access the User Menu.
2. Press COMMAND until SYSTEM TEST? displays.
3. The keypad displays SYSTEM PANICS. Select SYSTEM.
3. The System Test begins automatically and the keypad
displays the following messages in this order:
1) BELL SOUNDING during a two second bell test
2) KEYPAD SOUNDING all keypads assigned to the same
area sound their burglary alarm tone for two (2) seconds
during the keypad sounder test
3) BATTERY - OKAY or BATTERY - TRBL to indicate the
battery condition
4)* TRANSMIT TEST NO: 1 during the transmit test
5) TRANSMIT OKAY or TRANSMIT FAILED to show the
results of the transmit test
6) TEST END to indicate the System Test is complete.
7) You can press the Back Arrow key to end the transmit
test.
* The transmit test does not occur on local systems.

Table of Contents

Other manuals for DMP Electronics XR100